NPort 5200 Series Initial IP Address Configuration
3-7
4. The Property window opens automatically. From the Communication Parameter page, select the
appropriate COM port for the connection, COM1 in this example, and 19200 for Baud Rate, 8 for Data
Bits, None for Parity, and 1 for Stop Bits.
5. From the Property window’s Terminal page, select ANSI or VT100 for Terminal Type and then click OK.
If you select Dumb Terminal as the terminal type, some of the console functionsespecially the “Monitor
functionmay not work properly.
6. Press the “ ` ” key continuously and then power on the NPort 5200.
7. NPort 5200 will switch automatically from data mode to console mode as it receives a continuous “ ` ”string.
8. Input the password when prompted. Note that this page will only appear when the NPort 5200 has been set
up for password protection.