NOTE
Refer to the Universal® Condenser Manual for the Dip Switch instructions and settings for the condenser.
mrcool.com Page 16
Fig. 2.8 Fig. 2.9
Location of
Dip Switch on
Air Handler
Main Board
Unit Installation
Converting Unit From 5 Ton to 4 Ton
Follow these instructions during unit installation in order to enable a Universal® Series 5 ton
condenser and air handler split system to operate at 4 ton capacity.
1. DO NOT attempt this conversion while the unit is powered on.
2. Locate the capacity dip switch on the air handler main board. The capacity dip switch is circled on
the photo below.
3. The default position of the capacity dip switch is 2, 3 & 4 ‘Up’ and 1 ‘Down’ on both the SA2 and SA1
switches.
4. The default position of the capacity dip switch is 60k.
5. To activate the 48k capacity, flip capacity dip switch 1, 3 & 4 on SA2 and SA1 to Down. Flip capacity
dip switch 2 on SA2 and SA1 to Up.
Air Handler Field Conversion
DEFAULT 5 TON 4 TON SETTING
This is an example for switch
location only. Refer to fig. 2.8
and Fig. 2.9 above for settings.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool MDUI18060 and is the answer not in the manual?

MrCool MDUI18060 Specifications

General IconGeneral
ModelMDUI18060
TypeAir Handler
RefrigerantR410A
Airflow2000 CFM
Voltage208/230V
Phase1
Hertz60 Hz

Related product manuals