9010/9020 SIL Control Unit
Quick Start Guide
WARNING
The quick start guide does not replace the operating manual. It is imperative that the operating manual be read
and observed when using the device. In particular, the safety instructions, as well as the information for use,
operation and maintenance of the device, must be carefully read and observed.
19 inch Rack Version – Mechanical installation
9010 rack board version 9020 rack board version Rack for 2 modules (Panel cut out 124 x 133 mm)
Rack for 5 modules (Panel cut out 246 x 133 mm) Rack for 10 modules (Panel cut out 448 x 133 mm)
19 inch rack – Module Backplane Terminal Connection
ALARM CHANNELS A and B
FAILURE CHANNELS A and B
WARNING CHANNELS A and B
SENSOR CONNECTION CHANNEL A
SENSOR CONNECTION CHANNEL B (*)
CAUTION CHANNELS A AND B
ANALOG CHANNEL A+
HORN
(see the connection diagram on the
TECHNICAL DATA SHEET of the sensor used)
(see the connection diagram on the
TECHNICAL DATA SHEET of the sensor used)
not connected not connected
MAIN SUPPLY 100 - 230 VAC; 50 - 60 Hz
EARTH GROUND
BACK UP SUPPLY 24 VDC
HORN CUT OUT/ALARMS RESET (REMOTE)
ELECTRONIC EARTH (GROUND)
GND - EARTH (GROUND)
+ DATA
- DATA
RS 485
(120 Ohm termination resistor
across DATA+ and DATA- terminal
is required)
+ ANALOG OUTPUT CHANNEL B (*)
- ANALOG OUTPUT COMMON EARTH TO CHANNELS A AND B
(*) NOT USABLE WITH MODEL 9010
Wall Mount version – Terminal Connection
Wall Mount version – Mechanical Installation
Wall mount, 9010 SIL
Wall mount, 9020 SIL
Wall mounted unit installation instruction:
(1) Drilltheholesasshownbelowforthefourxingscrews.
(2) Remove the housing lid carefully. Watch the display cable being connected to the
lid inside.
(3) Fixtheunittothewall,byappropriatescrews(M5screwsor5mmSPAX).
(4) Closethelidwithexistingscrews.
WARNING
When opening the control unit housing, there is a risk of high voltage danger from relay contacts and main
power supply. Only authorised persons should open the control unit when it is switched off and secured against
unintentionalswitch-on.Beforeopeningthehousing,itmustbeconrmedthatpowerisoffforallpoles.
BACK UP SUPPLY
24 VDC
MAIN SUPPLY
100 - 230 VAC; 50 - 60 Hz
HORN CUT OUT/ALARMS RESET (REMOTE)
ELECTRONIC EARTH (GROUND)
RS 485
ALARM
CHANNELS A AND B
FAILURE
CHANNELS A AND B
WARNING
CHANNELS A AND B
CAUTION CHANNELS A AND B
HORN
ANALOG OUTPUTS +CHANNEL A (CHA),
+CHANNEL B (CHB), COMMON EARTH (COM)
SENSOR CONNECTION - CHANNEL A (M6) and CHANNEL B (M3)
(SEE THE SENSORS CONNECTION DATA SHEETS)
CHANNEL B NOT USED WITH MODEL 9010
S-TERMINAL IS NOT CONNECTED
(120 Ohm termination resistor
across DATA+ and DATA- terminal
is required)
www.MSAsafety.com
Schlüsselstrasse12
8645Rapperswil-Jona
Switzerland
10171753/01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSA 9010 and is the answer not in the manual?

MSA 9010 Specifications

General IconGeneral
BrandMSA
Model9010
CategoryControl Unit
LanguageEnglish