Page 39
Table 29 CL 3. Operability check of the Product
To be done
Routine
Man-hours per
1 Product
Operability check
of the Product
1 power the Product on;
2 make sure that OS has been successfully loaded
and the screen displays graphic data;
3 check that received data are displayed on the
screen and make sure that image has a high quality;
4 adjust backlight brightness if necessary;
5 check the controls (buttons) operability;
6 check the response of touch screen;
7 activate the screen menu, open tab page «Rx»
and check the reception (transmission) of NMEA
sentences and compliance of received and trans-
mitted data by three ports with the settings
1 person
15 minutes
3.4 PRESERVATION
The Product and set of operational documents are stored in preserved condition
in Manufacturer’s packaging boxes.
The time of re-preservation 2 years from the Manufacturer’s commissioning.
The preservation is done in full terms, for 2 years, applying protection and pack-
aging.
The re-preservation is done in heated rooms in the same order as the preservation.
The re-preserved Product, SPTA kit and documents are placed in package. The
time of storage for re-preserved Product is 2 years.