EasyManua.ls Logo

MSA EVOLUTION 5000 - 1 Before Use; Description; Introduction; About the Transmitter; Specifications

MSA EVOLUTION 5000
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
1 Before Use / Description
Introduction
Congratulations on the purchase of your new
MSA EVOLUTION
5000 Thermal Imaging
Transmitter. This handheld unit provides
advanced technology backed by years of MSA
quality, dedication, and service.
This high definition Transmitter provides the
latest in available transmission technology
Before Use / Description
The EVOLUTION 5000 Thermal Imaging
Transmitter is a highly sophisticated piece of
electronic equipment. The unit is designed to
withstand the firefighting conditions of heat,
driving spray, and frequent impact normally
seen in the Fire Service. Exsessive rough
handling may damage the Transmitter and
render it inoperable. It is not recommended
that the Transmitter run for extended periods
in high-heat conditions.
The EVOLUTION
5000 Thermal Imaging
Camera and Transmitter is intended as an aid
to fire and rescue operations, and training. It is
not a replacement for standard firefighting
techniques and precautions. Users must ensure
that the fire department´s standard operating
procedures are followed while using the
Transmitter.
About the Transmitter
The EVOLUTION
5000 Thermal Imaging
Transmitter is:
equipped with two user selectable channels
to provide the best transmission of images.
designed ergonomically for the firefighting
environment.
designed to easily attach to the
EVOLUTION
5000 TIC for rapid
deployment without compromising the
TIC´s design when not in use.
Specification
Construction Flame resistant,
water resistant,
externally mounted to
the TIC.
Height 210 mm, 8.5 in
Width 140 mm, 5.5 in
Approximate
Dimensions
Length 120 mm, 5 in
Weight w/ battery
w/o
battery
455 g, 16.1 oz
360 g, 12.7 oz
Power Source Rechargable Li Ion
battery
Power
Consumption
at room
temperature
max 430 mA when both
Channel LED´s are lit and
the battery LED is
flashing red
Operating
Time
1 Li Ion
battery
pack
> 4 hours
Transmitting
Power
EIRP 450 mW
Transmission
Range
Line of
sight
1 mile
Channel 1 Frequency 2458 MHz
Channel 2 Frequency 2474 MHz
This device complies with part 90 of the FCC
rules. Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation

Other manuals for MSA EVOLUTION 5000