GENERAL MAINTENANCE
After each use, inspect:
the Evolution 5200 TIC for structural, heat
and/or chemical damage
the mechanical hardware to ensure no
screws are loose
all lenses for heat damage, chemical
damage, cracks and breaks
to ensure that all warning labels are intact
battery - see "Battery Care and Installation"
NOTE: Thermal Imaging Cameras not meeting
the above inspection must be removed
from service until the proper repairs are
made by MSA.
charger and TIC LEDs for proper indication
that the system is operating properly.
Cleaning
After each use, clean all external surfaces (case,
base, visor, lens, window and straps) by wiping
with a solution of mild detergent and warm water.
Dry with a soft, lint-free cloth, to avoid scratching
the optical surfaces.
Periodically check connector terminals, video
socket, ON/OFF switch, locking latch and hinge
for contamination. Clean with a soft, lint-free cloth.
Do not remove the thermal imaging
camera cover or casing as the system
operates on high voltage. Only
authorized personnel may service the
unit.
FAILURE TO FOLLOW THE ABOVE
WARNING CAN RESULT IN SERIOUS
PERSONAL INJURY OR DEATH.
TROUBLESHOOTING THE TRUCK-
MOUNTED CHARGING SYSTEM
Troubleshooting Guidelines
SYMPTOM PROBLEM/SOLUTION
NO LEDs LIT
Check power connections.
Is power available?
Is the positive power lead connected
to the positive terminal?
External in-line fuse blown.
Replace fuse
Internal fuse blown. Replace fuse.
POWER LED STATUS
No batteries installed in the camera.
IS GREEN & CAMERA
Verify that there are good batteries in
BATTERY LED DOES
the camera
NOT LIGHT WHEN
Bad connection to the camera.
CAMERA IS PLACED
Make sure charger contacts are clean
IN CHARGER
and unbent. A small amount of contact
cleaner, such as WD-40, can be used
to clean charger and camera charging
contacts. Reseat firmly to
ensure connection .
POWER LED STATUS
Inspect battery contacts for dirt,
IS GREEN AND
corrosion or damage. Clean contacts
EXTERNAL BATTERY
or replace battery. Inspect the
LED DOES NOT LIGHT
contacts of the battery charger.
WHEN BATTERY IS
Verify they are clean, unbent, and
PLACED IN CHARGER
move down and spring back.
BATTERIES DO NOT
Out of operating temperature range.
FULLY CHARGE
Check that temperature of
environment and /or batteries is within
recommended operating range
Power source is noisy. Ensure power
hookup cable is connected to a clean
source without excessive voltage
spikes.
It is possible that charge can be ter-
minated abnormally. While this condi-
tion is rare, it can occur because of
external in-band noise that may reach
the charger electronics. In the unlike-
ly event that charge is falsely termi-
nated because of noise, the battery
may not fully charge. Always use the
camera battery gauge as an indicator
of battery condition.
Do not use solvents or paint thinners
to clean the Thermal Imager; other-
wise, the protective case may become
degraded.
"
CAUTION
"
WARNING
"
WARNING