Mode, press the POWER (green) button until:
• The display immediately returns to the
standard view and the 2X indicator is no
longer present.
NOTE: The 2X Digital feature replaces the
Standby-Mode feature on the
Evolution 5200HD
2
TIC.
The Evolution 5200 and Evolution 5200HD
2
TIC
come standard with five LED Indicators for System
Status, Battery Life and Overtemp status. When
the TIC is turned ON, all LEDs "flash" for two to
three seconds; then, the thermal picture appears.
When the TIC is turned OFF, all LEDs are
darkened. Also, the TIC has on-screen indicators
for low sensitivity, shutter and optional quick-temp
(FIGURE 4).
On-Screen Indicators
A Low sensitivity firefighting mode indicator
B Shutter indicator
C Optional Quick - Temp Indicator and Digital
Temperature Measurement
LED Indicators
D Over - Temperature Warning
E System Status Indicator
F Battery Status Indicators.
On-Screen Indicators
A - Low Sensitivity Mode Indicator -
An on-screen sensitivity indicator ("L") informs
the user when the camera is in the low
sensitivity mode.
• This mode occurs when the thermal imager
senses an environment above 160°C or
320°F.
• Dynamic Range is extended while in this
mode to provide greater image details of the
surroundings.
In high-heat conditions, the TIC will automatically
enter the Low Sensitivity mode. While in Low
Sensitivity mode, the TIC's dynamic range is
extended, thereby allowing the user to make better
distinction of objects and people within a higher
temperature range. When the Evolution 5200 TIC
is in Low Sensitivity mode, the letter "L" appears in
the lower left corner of the display.
B - Shutter Indicator -
An on-screen indicator that tells the user when the
TIC is shuttering appears as a green square in the
upper left corner of the display.
While the TIC is in operation, it is periodically
necessary for the TIC to refresh the focal plane in
order to operate properly. This occurs via an
internal shutter mechanism. When the TIC
shutters, the image on the display temporarily
freezes for about one second. Shuttering can
occur more frequently in higher heat conditions.
This is normal for all microbolometer - based TICs.
C - Optional Quick-Temp Indicator -
On-screen operating Quick Temp spotter and
vertical bar gauge spans temperatures from 0°F
(0°C) to 300°F (150°C) in High Sensitivity mode
and 0°F (0°C) to 1000°F (500°C) in Low Sensitivity
mode for objects located in the spotter. The digital
temperature feature displays the approximate
numeric value of the temperature of objects
located in the spotter.
G - Optional 2X Digital Zoom Indicator
on the Evolution 5200 TIC -
An on-screen indicator that tells the user when the
TIC display is in the Zoom mode, appears as
[ 2X ] in the lower center of the display.
LED Indicators
D - Over Temperature Warning -
Warning activates when the system electronics
approach maximum recommended operating
temperature limits.
• Not lit indicates system is within operational
thermal limits
• Flashing Red indicates the TIC has exceeded
recommended operational thermal limits.
Figure 4. Evolution 5200 and
Evolution 5200HD
2
TIC User Interface
5