EVOLUTION 6000 Thermal Imaging Camera
42
Technical Data
MSA
US
7 Technical Data
NFPA 1801, 2012 Edition Compliant (unless ordered otherwise, refer to the product label)
ANSI/UL 12.12.01 Class I, Div. 2 Groups A, B, C and D
Non-Incendive
Construction Flame retardant (material passes NFPA direct flame exposure test).
IP67 (withstands immersion to 3 feet (1 meter))
Approximate
Dimensions
Height 11.6 inches (295 mm)
Width 4.8 inches (122 mm)
Length 7.3 inches (185 mm)
Sensor Uncooled VOX microbolometer
Array size 320 X 240
Weight
(including battery)
EVOLUTION 6000 and
EVOLUTION 6000+
EVOLUTION 6000X
1.25 kg
1.31 kg
Power Source Rechargeable Li Ion battery
Operating time
(nominal 72°F, 22°C)
EVOLUTION 6000 and
EVOLUTION 6000+
EVOLUTION 6000X
2.5 to 3.5 hours depending on mode
2.0 to 3.0 hours depending on mode
Field of view 48° H; 37° V
Net equivalent temper-
ature difference
High sensitivity <78 mK, 40 mK typical
Low sensitivity <234 mK
Range Finder Maximum Range 210 ft (70 m)
Temperature
Measurement
±10 °C (18 °F) or ±10 %
whichever is greater
Image storage
(Evolution6000X only)
Number of images stored 1000 minimum
Format JPG
Video storage
(Evolution6000X only)
Length 4 h minimum
Format MPEG 4 elementary stream,
no audio
Start / Soak Temp Ambient Temperature Operating Time
Room Temp (20 - 23 °C) 80°C (176°F) >30 minutes
Room Temp (20 - 23 °C) 120°C (248°F) >20 minutes
Room Temp (20 - 23 °C) 260°C (500°F) > 6 minutes
Room Temp (20 - 23 °C) -40°C (-40°F) >25 minutes
Room Temp (20 - 23 °C) -30 C (-22°F) >40 minutes
Storage temperature
range
-40°C to +70°C (-40 °F to 158 °F).