G1 Facepiece
18
Cleaning, Disinfection
GB
5 Cleaning, Disinfection
The cleaning and disinfection of the masks is performed in accordance with the cleaning intervals
chapter 6.2.
WARNING!
Do not use cleaning products containing hydrocarbons or solvents [e.g. nitro-thinner].
Cleaned parts must not be dried in radiant heat [sun, radiators].
When using a drying cabinet, the temperature must not exceed +60°C.
Perform a tightness test (chapter 6.5) after every cleaning, disinfection and maintenance or after every
exchange of parts.
5.1 Preparing the Mask for Cleaning or Disinfection
(1) Remove inhalation and exhalation valve discs.
(2) Unbutton the nosecup.
(3) Removed components must be separately cleaned and disinfected.
(4) Dry mask and components and reassemble mask in reverse order.
(5) Perform a tightness test [ chapter 6.5].
5.2 Suitable Cleaning and Disinfection Procedures
WARNING!
Depending on lens type, only certain cleaning and disinfection procedures are permitted.
Only use the procedures permitted for the lens type, other procedures will damage the lens.
Follow the washing agent’s user instructions on this CD/DVD.
The power supply for the HUD (if applicable) is not part of the G1 Facepiece and is there-
fore not damaged during cleaning.
Procedure
Part number
washing instruc-
tion
Mask with
Standard Lens
(Marking P)
Mask with
Anti-Fog Lens
(Marking A)
Mask with
Anti-Scratch-
Lens (Marking H)
Cleaning/Disinfec-
tion by hand
10127480 XXX
Cleaning/Disinfec-
tion washing
machine (tumbling
type)
10127346 X---X