5. If moisture or condensation appears in the beacon:
Possible reasons:
a) Beacon not properly closed.
b) O-ring is damaged.
Solutions:
a) Retire the beacon from its site and move it to a dry site. Open and air it during
a few days. Put silica gel or any secant to absorb the humidity.
b) Check the O-ring and replace it if necessary.
c) Close the lens cover appropriately. Screws must be tightened in cross, to
exercise the same strength in the whole O-ring. Check the O-ring is in correct
position.
6. If the beacon doesn’t respond to the PC:
Possible reasons:
a) RS232 communication cable failure.
b) PC or software failure.
c) MF06 failure.
Solutions:
a) Check with other communication table.
b) Reinstall software or try with other PC.
c) Test MF06 flasher and substitute if necessary.