a) Register address 9000d: Local error of the connected GC device errors apply to the devices
not to the readings of these devices.
Here 0x8110: 0x0100 => MP error, 0x0010 => EEPROM or configuration error.
Nibble 4: =x
8
110 Nibble 3: =x8
1
10 Nibble 2: =x81
1
0 Nibble 1: =x811
0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Error Indicator, always 1 for
failures
Error Indicator, always 0 for
failures
Not used
Not used
Special mode ON
Not used
UPS detected
(only information)
Failure in connected devices
Maintenance information bit
Not used
Not used
Configuration error or EE
Flash failure
Not used
Power failure battery mode
Not used
UPS error
b) Register address 9001d 9096d: Local error of the connected devices like WSB2, SB2 or
MSB2. The errors concern the devices, but not the errors of the heads, because these are dis-
played in the registers of the measured values.
c) Register address 9097d 9104d: Local error of the 8 Gas Controller Modules (1x GC06 +
7x EP06))
Here 0x8100 = MP error, Error with any locally connected MP.
Nibble 4: =x
8
100 Nibble 3: =x8
1
00 Nibble 2: =x81
0
0 Nibble 1: =x810
0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
Bit 3
Bit 2
Bit 1
Bit 0
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Error Indicator, always 1 for
failures
Error Indicator, always 0 for
failures
Horn
feedback error
Warning sign
feedback error
Special mode ON
Not used
Not used
Failure in connected devices
Maintenance information bit
Over- / under-
temperature failure
Wrong analog output current
or relay failure
Configuration error or EE
Flash failure
CPU diagnostic errors
Over- / undervoltage failure
AD converter failure
Not used
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | GA_GC06_Modbus_supplement_E, 2022-04-05 | USA 221209 | Page 10 of 12
DGC6 Modbus Supplement – UserManual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSR ELECTRONIC Intec Controls PolyGard 2 GC-06 Series and is the answer not in the manual?

MSR ELECTRONIC Intec Controls PolyGard 2 GC-06 Series Specifications

General IconGeneral
BrandMSR ELECTRONIC
ModelIntec Controls PolyGard 2 GC-06 Series
CategoryController
LanguageEnglish