Problem Cause Remedy
Engine Fails to start 1. Engine flooded
2. Spark plug wire disconnected
3. Fuel tank empty or stale fuel
4. Engine not choked
5. Faulty spark plug
6. Throttle in stop position
1. Wait at least 10 minutes before starting
2. Connect wire to spark plug
3. Fill tank with clean, fresh gasoline
4. Choke engine
5. Clean, adjust gap or replace
6. Move throttle to FAST/Run position
Engine runs erratically 1. Spark plug wire loose
2. Spark plug scorched, defective or electrode
gap is set incorrectly
3. Stale fuel
4. Engine running with choke on
5. Water or dirt in fuel system
1. Connect and tighten spark plug wire
2. Re-adjust electrode gap or change
3. Fill tank with clean, fresh gasoline
4. Move choke to off
5. Drain fuel tank. Refill with fresh fuel
Engine overheats 1. Engine oil level low 1. Fill engine with proper amount of engine oil