2–10 Engine Data
2.4.2 12/16/18V 2000 Standby operation: Application Group 3D, Air-cooled
charge air, Optimized exhaust emission (EPA 40 CFR89 / Tier 1)
Explanation:
DL Ref. value: Continuous power (CP)
BL Ref. value: Fuel stop power (FSP)
A Design value
G G uaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Reference Conditions
Engine model 12 V
2000G43
12 V
2000G83
16 V
2000G43
16 V
2000G83
18 V
2000G83
Application group 3D 3D 3D 3D 3D
Intake air temperature
C
25 25 25 25 25
Charge-air coolant temperature
C
--- --- --- --- ---
Raw-water inlet temperature
C
--- --- --- --- ---
Barometric pressure mbar 1000 1000 1000 1000 1000
Site altitude above sea level
m
100 100 100 100 100
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders
12 12 16 16 18
Engine rated speed A
rpm
1800 1800 1800 1800 1800
Fuel stop power ISO 3046 FSP A kW 735 835 1000 1115 1250
GENERAL CONDITIONS (for maximum power)
Number of cylinders
12 12 16 16 18
Intake air depression (new filter)
(design)
A mbar 15 15 15 15 15
Intake air depression (limit
value)
L mbar 30 30 30 30 30
Exhaust backpressure (design) A mbar 30 30 30 30 30
Exhaust backpressure (limit
value)
L mbar 50 50 50 50 50
M015560/00E 03-05 ©MTU