4.7 Fuel treatment system – Switching on
Preconditions
The on-board power supply is switched on.
CAUTION
Damage to engine/plant.
Major material damage!
Before switching on, ensure that the engine/plant is ready for operation.
Before switching on, ensure that all housings are closed.
Before switching on, ensure that no work is in progress anywhere on the entire system.
Fuel treatment system – Switching on
1. Carry out checks prior to start-up (→ Page 48).
2. Switch on master switch on control cabinet.
Result: Signal lamp “Control voltage present” lights up.
3. Switch on switch for pump.
Result: Signal lamp “Pump running” lights up.
52 | Operation | M015650/03E 2011-10