General operating data
Number of cylinders
12V2000C
66R
Cold start capability: air temperature (w/o start aid, w/o preheating) -
(case A)
R °C 0
Firing speed, from R rpm 100
Firing speed. to R rpm 120
Inclinations, standard oil system (reference: waterline)
Number of cylinders
12V2000C
66R
Longitudinal inclination, continuous max. driving end down (option: max.
operating inclinations)
L Degrees (°) 15
Longitudinal inclination, continuous max. driving end up (option: max. op-
erating inclinations)
L Degrees (°) 15
Transverse inclination continuous max. (option: max. operating inclina-
tions)
L Degrees (°) 15
Capacities
Number of cylinders
12V2000C
66R
Engine coolant capacity, engine side (without cooling equipment) R Liters 63
Charge-air coolant, engine side R Liters 25
Total engine oil capacity, initial filling (standard oil system) (option: max.
operating inclinations)
R Liters 99
Oil change quantity max. (standard oil system) (option: max. operating in-
clinations)
R Liters 87
Oil pan capacity dipstick mark min. (standard oil system) (option: max. op-
erating inclinations)
L Liters 73
Oil pan capacity dipstick mark max. (standard oil system) (option: max. op-
erating inclinations)
L Liters 81
Weights / Main dimensions
Number of cylinders
12V2000C
66R
Engine weight, dry (basic engine configuration acc. to scope of supply
specification)
R kg 2950
Acoustics
Number of cylinders
12V2000C
66R
Exhaust noise, unsilenced - BL (free-field sound pressure level Lp, 1m dis-
tance, ISO 6798, +3dB(A) tolerance)
R dB(A) 103
Exhaust noise, unsilenced - BL (sound power level LW, ISO 6798+3 db(A)
tolerance)
R dB(A) 116
26 | Product Summary | MS150094/02E 2015-05