536 – AL Wiring PWM_CM1
Yellow alarm; warning
Cause Corrective action
Wire break or short circuit on
channel PWM_CM1.
u Check wiring to connected device or check connected device
(actuator/sensor), replace as necessary.
549 – AL Power Cut-Off detected
Entered in fault memory only.
Cause Corrective action
The operating voltage of the
Engine Control Unit was switched
of with the engine running. This
may lead to overpressure in the
HP fuel system, which might
cause damage to the engine.
u Instruct the operator only to disconnect the power supply when the
engine has stopped.
551 – SS Engine Overspeed Camshaft
Red alarm, emergency stop
Cause Corrective action
Engine overspeed, camshaft. u Restart engine (→ Page 36).
558 – AL Wiring PWM_CM2
Yellow alarm; warning
Cause Corrective action
Wire break or short circuit on
channel PWM_CM2.
u Check wiring to connected device or check connected device
(actuator/sensor), replace as necessary.
582 – AL Emergency Stop Failure
Entered in fault memory only.
Cause Corrective action
Emergency stop command was
not executed.
u Contact Service.
596 – AL Cons. Parameter Record
Yellow alarm; warning
Cause Corrective action
Standard production data record
available. The data record stored
is for testing.
u Contact Service.
70 | Troubleshooting | MS150094/02E 2015-05