Fault
code no. Full designation Meaning Action
Setting parame-
ter no.
346 AL Open Load Cylinder
A6
Disruption fault in injector
wiring cylinder A6. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.545
347 AL Open Load Cylinder
A7
Disruption fault in injector
wiring cylinder A7. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.546
348 AL Open Load Cylinder
A8
Disruption fault in injector
wiring cylinder A8. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.547
349 AL Open Load Cylinder
A9
Disruption fault in injector
wiring cylinder A9. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.548
350 AL Open Load Cylinder
A10
Disruption fault in injector
wiring cylinder A10. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.549
351 AL Open Load Cylinder
B1
Disruption fault in injector
wiring cylinder B1. Result:
Misfiring (alarm configuration
parameter, see PR
2.8008.100 for explanation).
Check injector wir-
ing, exclude disrup-
tion in solenoid
valve (e.g. by injec-
tor replacement).
Fault rectification:
After each working
cycle.
1.8004.550