8.7 Fuel System
8.7.1 Fuel system – Venting
Preconditions
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Diesel fuel
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Venting LP fuel system
1. Loosen flushing/return line of HP pump at
connection (1).
2. Unlock fuel priming pump (2), screw out han-
dle.
3. Operate the fuel priming pump (2) with the
handle until bubble-free fuel comes out of the
connection (1).
4. Lock fuel priming pump (2), screw in handle.
5. Verify that fuel priming pump (2) is locked:
handle must be tightened.
6. Tighten connection (1) of flushing/return
line.
M015565/03E 2016-02 | Fuel System | 91