MULTI-MOVER XL50
15
8 FAILURES
When removing a failure, ALWAYS switch off the Multi-Mover XL50 and
remove the ignition key.
If a defect is established at the Multi-Mover XL50, do not use it until the repair has been com-
pleted.
Failure Solution
A The Multi-Mover XL50 does not drive.
1 Emergency stop has been pressed 1 Pull out
2 Battery empty 2 Charge battery
3 Battery clamps make poor contact 3 Clean, attach again
4 Direction switch defective 4 Replace switch
5 Other causes. 5 Consult your dealer
6 Electric brake uncoupled 6 Press brake handle
B The Multi-Mover XL50 functions occasionally.
1 Loose wiring 1 Check wiring
2 Dirty or worn carbon brushes 2 Clean or replace if less than 1 cm. long
3 Dirty or worn collector motor 3 Clean, or have it overhauled, or replace it
4 Relay does not come "in" properly due to contamination or defect 4 Clean or replace
C Speed cannot be controlled (properly), or it drives at high speed immediately.
1 Speed controller defective 1 Replace
2 Relay defective 2 Replace
In case of a failure not mentioned in the list above, please contact your dealer.
Note: In the warranty period, it is absolutely prohibited to perform repairs, changes and
modifications or anything like that to the Multi-Mover XL50, the warranty will become invalid
automatically.
9 PARTS
001 Battery (state amperage)
002 Drive motor
003 Carbon brush set
004 Relay
005 Speed switch
006 Ignition lock
007 Reverse switch forward - reverse
008 Drive wheel
009 Swivel wheel
010 AXLE for benefit of drive wheels
011 Battery plug
012 Female plug for battery plug
013 Fuses, set
014 Main fuse
020 Symbol stickers