Do you have a question about the multicomp pro MP760607 and is the answer not in the manual?
The Multicomp Pro AC/DC Clamp Meters, models MP760607 and MP760608, are portable True RMS clamp meters designed for safe and reliable electrical measurements. These devices offer a comprehensive set of functions for various applications, from basic electrical troubleshooting to more advanced diagnostics.
The core function of these clamp meters is to measure AC and DC current without breaking the circuit, achieved by clamping the jaws around a single conductor. The MP760607 model supports current measurements up to 400A, while the MP760608 extends this capability to 600A. Both models provide True RMS measurement, ensuring accurate readings for non-sinusoidal waveforms, which are common in modern electrical systems.
Beyond current measurement, these devices are equipped to measure AC and DC voltage, allowing users to check power supply levels and circuit integrity. They also feature resistance measurement for checking continuity and identifying open or short circuits, and capacitance measurement for testing capacitors. The MP760608 model further includes temperature measurement capabilities, making it suitable for applications where thermal analysis is required.
Frequency measurement is another key function, enabling users to verify the frequency of AC signals, which is crucial for many electronic and power systems. The meters also incorporate a continuity test with an audible buzzer for quick checks of circuit paths, and a diode test for evaluating the functionality of semiconductor diodes.
A notable safety feature is the Non-Contact Voltage (NCV) electric field detection. This allows users to detect the presence of AC voltage without direct contact, enhancing safety by identifying live wires before physical interaction. The NCV function provides both audio and visual indications of voltage presence, with varying sensitivity levels (EFHI and EFLo) to accommodate different voltage intensities.
The Multicomp Pro clamp meters are designed for ease of use and enhanced user experience. They feature an automatic ranging function, which simplifies operation by eliminating the need for manual range selection. The large LCD display provides clear and easy-to-read measurements, and a fast refresh rate (3 times/s) ensures responsive readings. For low-light conditions, a backlight can be activated, improving visibility of the display.
Several buttons enhance the usability of these meters. The "SELECT" button allows users to switch between different functions or ranges within a composite scale, offering flexibility in measurement modes. The "HOLD/BACKLIGHT" button serves a dual purpose: a short press activates data hold, freezing the current reading on the display for convenient recording, while a long press toggles the backlight on or off.
For analyzing fluctuating signals, the "MAX/MIN" button is invaluable. It enables the meter to record and display the maximum and minimum values measured over a period, which is particularly useful for identifying voltage sags, surges, or current peaks. The "REL" (Relative) button allows users to set a reference point for measurements. When activated, subsequent readings are displayed as a difference from this stored reference, which is beneficial for zeroing out test lead resistance or comparing measurements against a baseline.
Safety is paramount in the design of these meters. They are built to EN61010-1, 61010-2-032/033 safety standards, ensuring protection against electrical hazards. Full-function protection is integrated to prevent damage from false detections, such as applying high voltage to a current measurement range, and they include over-voltage and over-current alarms. The jaw opening is designed to accommodate conductors up to 28mm in diameter, making them versatile for various cable sizes.
The meters are also equipped with an auto power-off function, which conserves battery life by automatically shutting down the device after 15 minutes of inactivity. This feature can be disabled if continuous operation is required. A low battery indication symbol on the LCD alerts users when the battery voltage is low, and a low battery shutdown prompt ensures that measurements are not taken with insufficient power, which could affect accuracy.
Maintaining the Multicomp Pro clamp meters is straightforward, focusing on ensuring their longevity and continued accuracy. General maintenance involves keeping the meter casing clean with a soft cloth and mild detergent, avoiding abrasive cleaners or solvents that could damage the device. Users are advised to regularly inspect the meter and test leads for any signs of damage or abnormal behavior before each use. If any issues are found, the device should not be used, and professional service should be sought.
Battery replacement is a simple process. When the low battery symbol appears on the LCD, the two standard AAA 1.5V batteries should be replaced promptly to maintain measurement accuracy. The manual provides clear instructions on how to access the battery compartment and replace the batteries, emphasizing correct polarity. For prolonged storage, it is recommended to remove the batteries to prevent leakage and potential damage to the meter.
The device is designed with a robust construction, including 1m drop protection, to withstand typical work environments. However, it is important to avoid exposing the meter to high temperatures, humidity, flammable, explosive, or intense magnetic environments, as these can affect its performance and safety. The internal circuitry should not be altered by users, as this could lead to damage to the meter and pose a safety risk.
The product is also designed with environmental responsibility in mind. At the end of its life, it should be treated as Waste Electrical & Electronics Equipment (WEEE) and disposed of separately from general household waste, in accordance with local recycling schemes. This ensures that the materials are recovered and recycled responsibly.
| Category | Measuring Instruments |
|---|---|
| Model | MP760607 |
| Brand | Multicomp Pro |
| Type | Digital Multimeter |
| DMM Type | Handheld |
| Display Type | LCD |
| Display Digits | 3.5 |
| Voltage DC Max | 600V |
| Voltage AC Max | 600V |
| Current DC Max | 10A |
| Current AC Max | 10A |
| Diode Test | Yes |
| Continuity | Yes |
| Battery Type | 9V |
| Auto Power Off | Yes |
| Safety Rating | CAT II 600V |
| DC Current Range | 200µA to 10A |
| AC Current Range | 200μA, 2mA, 20mA, 200mA, 10A |