TESTING IN CAT II MEASUREMENT LOCATIONS
CAT III shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall
outlets. Take care not to lose the shields.
11. Technical Specications
Accuracy: ± (%reading + counts), the calibration period is 1 year.
Ambient temperature and humidity: 23°C±5°C; ≤80%RH.
Temperature coecient: the accuracy assured temperature condition is 18°C ~ 28°C, the range of ambient temperature
uctuation is stable within ±1°C. When the temperature is less than 18°C or over 28°C, the additional temperature coecient
error is 0.1 x (specied accuracy)/°C
11.1 Current Measurement
AC Current
Range
Resolution Accuracy
MP60607 MP60608
40.00A 60.00A 0.01 A
±(2%+5)
400.0A 600.0A 0.1 A
DC Current
Range
Resolution Accuracy
MP60607 MP60608
40.00A 60.00A 0.01 A
±(2%+5)
400.0A 600.0A 0.1 A
Caution:
• Accuracy guarantee range: 5%~100% of range
• When the measured current reaches the warning value, there will be an alarm sound (MP60607: 410A, MP60608: 610A)
• With DC current DCA mode, LCD may display non-zero value in open circuit state, users can press “REL” button to clear
display to zero before each measurement.
11.2 Voltage Measurement
DC Voltage
Range
Resolution Accuracy
MP60607 MP60608
400.0mV 600.0mV 0.1mV ±(0.7 +3)
4.000V 6.000V 0.001V
±(0.5 +3)
40.00V 60.00V 0.01V
400.0V 600.0V 0.1V
600V - 1V