Galvanized Box Fan 130
INS00025-A Original instructions ENGLISH | 7
Explanation type plates
3. Wiring diagram 27. Insulation class 51. Air volume at 0 Pa (m
3
/h)
4. Voltage (V) 28. TEAO (Totally Enclosed Air Over) 52. Static pressure (x Pa)
5. Frequency (Hz) 29. Number of phases 53. Air volume at x Pa (m
3
/h)
6. Nominal current (A) 30. Manufacturers name 54. PSE-logo
7. Rotation speed (RPM) 31. Manufacturers address 55. Fan current (A)
8. Power (kW or PK) 32. Manufacturers country 56. Pressure at 0 inwg.
9. Cos phi 33. cURrus logo 57. Air volume at 0 inwg.CFM
10. Service factor 34. CE-logo 58. Pressure at –x- inwg.
11. Service factor ampere 35. CSA-logo 59. Air volume at –x- inwg.
12. Full load ampere 36. W333 bin 60. Max. ambient temperature °F
13. Capacitor (µF/V) 37. Tester code 61. Min. ambient temperature °F
14. Max. ambient temperature °C 38. Work order date 62. Order
15. Min. ambient temperature °C 39. Fan type 63. CCC-logo
16. IE2 40. Imax (A) 64. Motor data. For…..
17. µ 100% 41. P 65. House code
18. µ 75% 42. VSD used 66. Acceptable for field wiring
19. µ 50% 43. Part number customer 67. Min
-1
application
20. Thermal protection (*) 44. Weight (kg) 68. Cos phi application
21. Year of construction 45. Controllability (**) 69. Wiring diagram application
22. Bar code 46. Energy efficiency category 70. QR code
23. Winding diagram 47, Energy efficiency static or total 71. Rotor code
24. Weather proof 48. µ Overall 72. EAC logo
*) Thermal protection (NC) (for single phase: 250V 10A cos Φ =1 / for 3-
phase: 250V 2.5A cos Φ =1)
**) E = suitable for electronic voltage control (TRIAC / phase cutting).
**) T = suitable for transformer voltage control.
**) F = suitable for frequency control / VFD (Variable Frequency Drive).
A frequency controller in combination with a single phase motor is possible.
A QR-code is displayed on the rating plate. This QR-code contains a link to
an information page about this product. Here you can find a digital copy of
these instructions as well as other information about this product.
5.4 Intended use
This Galvanized Box Fan 130 is intended to be used as an exhaust fan for the
mechanical ventilation of livestock houses (pigs, poultry, dairy) and
greenhouses or industrial applications.
NOTICE
This fan is intended for moving air only.
DANGER
Do not use this fan in explosive or potentially explosive atmo-
spheres.
5.5 Technical information
Sound pressure levels are measured at a distance of 2 meters and corrected
for the human ear (A-weighting) in dB(A). The technical datasheet contains
calculated sound pressure levels in dB(A) at a distance of 7 meters assuming
free field conditions.
Technical specifications regarding performances are guaranteed until 1000
meters above sea level.
For detailed technical information please visit our website from which
technical datasheets can be viewed and downloaded.
http://productselector.vostermans.com
5.6 Other information
DANGER
Ventilation system failure
This fan is manufactured to the highest quality standards. Neverthe-
less, failure of a fan can always occur.
This fan is intended to be used as a component of a ventilation sys-
tem. Where the health and well-being of humans and/or animals is
dependent on the functioning of this ventilation system, an appropri-
ate backup system must be provided such that in the event of failure
of the main system, sufficient air renewal is guaranteed to preserve
the health and well-being of the humans and/or animals.
An alarm system, which will operate even if the principal electricity
supply to it has failed, must be provided to give warning of any fail-
ure in the system.
6 Installation
WARNING
Installation must be carried out by skilled persons only!