IDS001 Document Scanner User Manual
Version 1.00
Figure 3-3 Formatting SD Card
3) When “F” is displayed on LCD screen, press the FORMAT” hole again to cancel formatting the SD card
and exit
3.3. White Balance Calibration
If the scanned image appears blurry, lines and other problems, performing white balance calibration operations
can reorganize the data.
1) Clean the CIS with cleaning cloth.
Figure 3-4 Clean the CIS
2) Put the scanner on a white paper.
3) Press the “SCAN” button for 2s to turn on the scanner.
4) While holding down the "JPG/PDF" button, press the "SCAN" button to enter the calibration mode. (The
red and green lights will on at the same time)
Figure 3-5 White Calibration