3.1 Switch Functions
Figure 2 illustrates the front panel and Table 1 lists the available switch functions.
Figure 2: Controller Front Panel
LED
When On
Controller Alarm
Indicates controller failure
Heat Stage
Heat stage is active
Cool Pad Stage Cool pad stage is active
Cool Stage 1/2/3
Cool stage is active
Table 1: Available Switch Functions
Switch
Function
Inlet/Tunnel
Toggles between ventilation methods:
Inlet: One or two vents open.
Tunnel: Tunnel curtain opens in case of backup
operation
Ventilation method depends on the livestock
age, the equipment in the house, and the
season of the year. Important: Refer to Inlet or
Tunnel Air Source, page 7.
Latch On/Off
Latch ON: Once Thermostat 4 (Cool Stage 2) is
activated, the RBU continues to run in Cool Stage
2 (Fans 1-10) until switched off manually.
Latch OFF: RBU runs Cool/Heat Stages
according to thermostats.
You can use the Latch feature to lock the
facility into tunnel mode for an extended period.
This may help remove built up heat stress in
your poultry.