AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020000 6
Data logger
Recorded production data, meter values and temperatures can be read off at any time. The
respective values can be selected using the "Open" button. These can be presented in the three
views of the current year, month or day using the "Calendar" button.
TIP: Type directly in the diagram on the individual bars to present the data in their
next level of definition and on the button of the data logger again to return to the
previous level.
The following data can be displayed:
Total power: Shows the total power figures for all the connected loads. The yellow bars indicate the
PV excess power used, the green bars the proportion of grid energy when the optional temperature
boost backup is active.
Meter: indicates the value of the total power drawn from the grid (red) including household loads
and grid feed-in (green) at the metering point.
Power 1: shows the power data for load 1.
Power 2: shows the power data for load 2.
Temperature 1-4: shows the data of the temperature probe.
Status information on the display
The data of all variables relevant to the operation are shown in a list.
Output: shows the current output of the AC•THOR power unit.
Meter: shows the current data for the meter at the measuring point. A positive value shows drawing
from the grid, a negative value, feeding into the grid.
PV: If a corresponding measuring point has been set in the Web-Interface under Setup, the value of
the PV power is available here. See Measurement Settings.
Load: shows the nominal power of the load (at 230 V) which is currently being supplied by the
AC•THOR output unit. This value can be determined from an output of 500 W.
With AC•THOR 9s, the load status (0 or 1) at the three outputs is displayed at this point.
Temperature 1: Current data probe 1
Temperature 2: Current data probe 2
Temperature 3: Current data probe 3
Temperature 4: Current data probe 4
IP: shows the current IP address of the AC•THOR.