AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020000 7
Ctrl IP: shows the current IP address of the signal source. Shown in addition in the line below is the
designation of the signal source and the current measured value. A positive value shows drawing
from the grid, a negative value, feeding into the grid.
Status: Shows the unit's current status. See chapter "Status codes".
For AC•THOR 9s the number consists of two parts. On the left the status code of power unit
AC•THOR 9s, on the right the status code of power unit AC•THOR.
Grid voltage: shows the current input voltage at the AC•THOR (only with AC•THOR)
Grid power: shows the current input power at the am AC•THOR (only with AC•THOR)
Output voltage: shows the current output voltage of the AC•THOR (only with AC•THOR)
Power 1: Power at output Out-1 (only with AC•THOR 9s)
Power 2: Power at output Out-2 (only with AC•THOR 9s)
Power 3: Power at output Out-3 (only with AC•THOR 9s)
Frequency: shows the current grid frequency. This information is of particular interest in operating
mode M8.
Temperature output unit: shows the current temperature of the AC•THOR power electronics.
Fan: shows the current speed setting of the internal fan.
Serial number: shows the unit serial number.
MAC address: shows the MAC address of the unit.
Version: shows the current firmware version of the unit.
Version power stage: shows the current firmware version of the AC•THOR output unit.
For AC•THOR 9s the firmware version of the PS consists of two parts.
pXXX: Power stage AC•THOR
sXXX: Power stage AC•THOR 9s
Device number: shows the unit number set. This is also visible on the home screen.
Operating mode: shows the operating mode set (M1 – Mx). This is also visible on the home screen.
Latest firmware: shows the latest firmware version, or "current" is displayed.
Update status: Ok, loading (number of files), or waiting for installation
Output unit update status: Ok, loading, or waiting for installation
Ethernet (E) Firmware: Shows the status of the firmware, last version, update progress.
Power stage (P) Firmware: Shows the status of the firmware, last version, update progress.
Power stage 9s (S) Firmware: Shows the status of the firmware, last version, update progress.
Relay status: shows the current status of the switch output (0 or 1).
For AC•THOR 9s this number has four digits. The first digit shows the status of the switch output (0
or 1), the second digit whether Out-3 is switched (0 or 1), the third digit whether Out-2 is switched
(0 or 1) and the fourth digit shows the output that is currently supplied by the power stage (1, 2 or
3).
Settings
See chapter "General settings" for general unit settings, also chapter "Operating modes" for settings
specific to the respective operating mode.