ULTRAPEN
PT1
Conductivity/TDS/Salinity Pen
ORIGINAL
EDITED FOR USE
Minimum height 5 mm
S
ACCURATE
S
RELIABLE
S
SIMPLE
Professional Water Analysis
Accuracy of ±1% of READING
±.2% at Calibration Point
Reliable Repeatable Results
KCl, NaCl and 442™ Natural Water Modes
Automatic Temperature Compensation
Autoranging
Waterproof
Powered by 1 N Type battery (included)
PACKAGE CONTENTS:
PT1 Pocket Tester Pen - battery installed•
Scoop•
Pocket Clip•
Holster•
Lanyard•
Operating Instructions•

Other manuals for Myron L ULTRAPEN PT1

Question and Answer IconNeed help?

Do you have a question about the Myron L ULTRAPEN PT1 and is the answer not in the manual?

Myron L ULTRAPEN PT1 Specifications

General IconGeneral
Resolution (pH)0.01 pH
Temperature CompensationAutomatic
IP RatingIP67
Resolution0.1 °C/°F
Measurement Range (pH)0 - 14 pH
Temperature Range0 - 50 °C (32 - 122 °F)
Accuracy+/- 0.01 pH
Operating Temperature0 to 50°C (32 to 122°F)
Battery Life>100 hours
Measurement Range (Conductivity)0 to 1999 µS/cm
Resolution (Conductivity)1 µS/cm
Calibration (pH)1-point (4.0, 7.0, or 10.0)
Power Source1 x N Type Battery

Summary

Product Overview and Package Contents

Professional Water Analysis Features

Highlights the accuracy, reliability, and simplicity of the pen.

Package Contents

Lists all items included in the PT1 tester package.

Introduction and Specifications

Product Introduction

Overview of the Myron L ULTRAPEN PT1's design and capabilities.

Technical Specifications

Details measurement range, accuracy, resolution, power, and physical properties.

Operating Instructions and Calibration

Solution Selection

Guide to selecting the correct measurement mode for the PT1 tester.

Temperature Unit Selection

Instructions for setting temperature units (Celsius or Fahrenheit).

Normal Operation

Steps for performing measurements, including rinsing and dipping the pen.

Calibration Procedures

Instructions for Wet and Factory Calibration of the PT1 tester.

Maintenance and Quick Reference

Quick Reference Instructions

Condensed steps for turning on and using the PT1 pen.

Battery Replacement

Guide to replacing the battery in the PT1 tester.

Routine Maintenance

How to clean and maintain the PT1 pen for optimal performance.

Accessories

Information on calibration solutions and other available items.

Related product manuals