17
Feature 04 – Frost Protect Temperature: This is the
temperature maintained when the thermostat is in frost
mode. The range is 6 - 17°C, the default is 6°C.
Feature 05 – Output Delay: To prevent rapid switching, an
output delay can be entered. This can be set from 00 to 15
minutes. The default is 00, which means there is no delay.
Feature 06 – Communication Address: This setting
does not apply to this model.
Feature 07 – Temperature Up/Down Limit: This function
allows you to limit the use of the up and down temperature
arrow keys. This limit is also applicable when the thermostat
is locked and so allows you to give others limited control over
the heating system.
Feature 08 – Sensor Selection: On this thermostat, you can
select which sensor should be used. You can select between
built in air temperature only, remote air sensor only or built in
sensor&oortemperature.Whenyouenableoption02(built
in&oor)theoorsensorisusedasaoorlimitingsensorand
is designed to prevent the floor from overheating.