23 / 24
Specification
11. The Display Method of Measurement Data
The average data of welding time, welding current, and the tip voltage is displayed as this device.
Arithmetic means of effective value, effective value for each cycle, waveform of welding time,
welding current, the tip voltage , and tip resistance are displayed as PDA or PC.
12. Auto-power-off
After an external trigger and setting item change are lost, it is after 10 minutes, 30 minutes, and 60
minutes (selection). It power-supply-turns off.
13. Preservation of Measurement Data
Measurement data is saved on the main part of a measuring instrument.
(1) Average data : 10000 data
(2) Each cycle/msec : 20 data
(3) Wave data : 1 data
Preservation by the Comma Separated Value is possible at PC (edit is possible at Excel etc.).
14. External Output Radio communications (Bluetooth), USB
15. Power Supply Built-in rechargeable battery (Li-ion 780mAh)
16. Charge Time About 5 hours
17. Operation time Continuation 8 hours
18. Power Consumption
During standing : 63 mA
During wireless communication : 115 mA
19. Overall dimensions 58(h) x155(w) x22(d)
20. Weight About 170g
21. Operation Temperature 0-40 degrees C
22. Operation Humidity 10 - 90% (No dew)
23. Accessories
- CT coil
- Tip voltage detection cable
- AC adapter (AC100V/120V)
24. Option
Software (for PC): Inspector.exe (Windows XP, 2000, ME correspondence)
Software (for PDA) :Pocket Inspector.exe (Windows CE3.0 correspondence)
A USB cable, CF card for Bluetooth, the USB adapter for Bluetooth
* Specification may be changed without a preliminary announcement for improvement.