NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 2
NAPCO Security Group
Programming Instructions, Volume 2 Page 105
ADDRESS 5640
EZM Group 61
ZONES 249-252
ADDRESS 5641
EZM Group 62
ZONES 253-255
EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will
activate the PGM Lug on the corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone
EZMs are used each one is treated as TWO zone groups. NOTE: Lug goes ACTIVE (low) when ANY selected area
is armed. When activated, the PGM Lug goes negative (to Ground).
1. Select the desired group number.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct
Address Programming Example on page 72.
3. Press U to save.
GROUP
NUMBER
EZM PGM TERMINAL CONTROL
ADDR A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
1 5648
2 5649
3 5650
4 5651
5 5652
6 5653
7 5654
8 5655
9 5656
10 5657
11 5658
[Default = blank (•) blank (•) from address 5648-5658]
GROUP
NUMBER
EZM PGM TERMINAL CONTROL
ADDR A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
12 5659
13 5660
14 5661
15 5662
16 5663
17 5664
18 5665
19 5666
20 5667
21 5668
22 5669
[Default = blank (•) blank (•) from address 5659-5669]
EZM PGM TERMINAL CONTRO L (ADDRESS 5648-5669)
NOTE: Zones 1-8 are included in the control panel and Zones 9-255 (Groups 1-62) are available as EZM Zones (either Wireless or Hardwired).
EZM TYPE
DATA ENTRIES
(RIGHT)
OPTION
blank (•)
Not used (No
EZM present)
1 4-Zone EZM
EZM GROUP OPTIONS: Up to 62 Groups of 4 Zones each may be programmed
depending on the number of zones used and which EZM modules are connected. Each
group represents 4 zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations above.
3. Press U to save