NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 2
NAPCO Security Group
Programming Instructions, Volume 2 Page 107
AREA OUTPUT CONT ROL OPTIONS (ADDRESS 5780 -5819)
AREA OUTPUT TURNS OFF UPON DISARM: Select options for any of the 5 Outputs per area when disarming a particular area.
1. Select the desired option.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct Address
Programming Example on page 72.
3. Press U to save.
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 5 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5784
Pulsed Burg. Bell 5792
Burg PGM2 5800
Burg Relay 5808
Burg PGM1 5816
[Default = blank (•) blank (•) from address 5784-5816]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 6 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5785
Pulsed Burg. Bell 5793
Burg PGM2 5801
Burg Relay 5809
Burg PGM1 5817
[Default = blank (•) blank (•) from address 5785-5817]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 2 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5781 ON
Pulsed Burg. Bell 5789 ON
Burg PGM2 5797
Burg Relay 5805
Burg PGM1 5813
[Default = Noted above with "ON"]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 3 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5782
Pulsed Burg. Bell 5790
Burg PGM2 5798
Burg Relay 5806
Burg PGM1 5814
[Default = blank (•) blank (•) from address 5782-5814]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 4 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5783
Pulsed Burg. Bell 5791
Burg PGM2 5799
Burg Relay 5807
Burg PGM1 5815
[Default = blank (•) blank (•) from address 5783-5815]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 7 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5786
Pulsed Burg. Bell 5794
Burg PGM2 5802
Burg Relay 5810
Burg PGM1 5818
[Default = blank (•) blank (•) from address 5786-5818]
OUTPUT SILENCED
(TURNED OFF)
DISARMING AREA 8 TURNS OFF AREA OUTPUT
ADDR
A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
Burglary Bell 5787
Pulsed Burg. Bell 5795
Burg PGM2 5803
Burg Relay 5811
Burg PGM1 5819
[Default = blank (•) blank (•) from address 5787-5819]