NAPCO Gemini C-Series Control Panel Installation Instructions--Volume 2
Page 20 Installation Instructions, Volume 2
OUTPUT
Dealer
Entered
Name
OUTPUT TYPE
OUTPUT DEVICES
GEMC-FW-SLC GEMC-BSLC
GEMC-OUT8
or
GEMC-RM3008
GEMC-FW-
SLC RELAY
DIP SWITCH
SETTING
IS DEVICE
SOM?
Y/N
IS DEVICE
1st relay of
RM2?
Y/N
IS DEVICE
2nd relay of
RM2?
Y/N
FWC-FSLC-
SOM1 OR
FWC-FSLC-
RM2
PRO-
GRAMMED
ADDRESS
GEMC-BSLC
RLY SWITCH
GEMC-BSLC-
RLY Dial ADD.
JUMPER
ADD.
OUTPUT #
NAC ADDR
Shunts
OUTPUT #
EXT OUT 41 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
6 86 6 4 1 6 1 N/A N/A
EXT OUT 42 N/A 6 85 6 4 2 6 2 N/A N/A
EXT OUT 43 N/A 6 84 6 4 3 6 3 N/A N/A
EXT OUT 44 N/A 6 83 6 4 4 6 4 N/A N/A
EXT OUT 45 N/A 6 82 6 4 5 6 5 N/A N/A
EXT OUT 46 N/A 6 81 6 4 6 6 6 N/A N/A
EXT OUT 47 N/A 6 80 6 4 7 6 7 N/A N/A
EXT OUT 48 N/A 6 79 6 4 8 6 8 N/A N/A
EXT OUT 49 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
7 78 7 4 9 7 1 N/A N/A
EXT OUT 50 N/A 7 77 7 5 0 7 2 N/A N/A
EXT OUT 51 N/A 7 76 7 5 1 7 3 N/A N/A
EXT OUT 52 N/A 7 75 7 5 2 7 4 N/A N/A
EXT OUT 53 N/A 7 74 7 5 3 7 5 N/A N/A
EXT OUT 54 N/A 7 73 7 5 4 7 6 N/A N/A
EXT OUT 55 N/A 7 72 7 5 5 7 7 N/A N/A
EXT OUT 56 N/A 7 71 7 5 6 7 8 N/A N/A
EXT OUT 57 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
8 70 8 5 7 8 1 N/A N/A
EXT OUT 58 N/A 8 69 8 5 8 8 2 N/A N/A
EXT OUT 58 N/A 8 68 8 5 9 8 3 N/A N/A
EXT OUT 60 N/A 8 67 8 6 0 8 4 N/A N/A
EXT OUT 61 N/A 8 66 8 6 1 8 5 N/A N/A
EXT OUT 62 N/A 8 65 8 6 2 8 6 N/A N/A
EXT OUT 63 N/A 8 64 8 6 3 8 7 N/A N/A
EXT OUT 64 N/A 8 63 8 6 4 8 8 N/A N/A
EXT OUT 65 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
9 62 9 6 5 9 1 N/A N/A
EXT OUT 66 N/A 9 61 9 6 6 9 2 N/A N/A
EXT OUT 67 N/A 9 60 9 6 7 9 3 N/A N/A
EXT OUT 68 N/A 9 59 9 6 8 9 4 N/A N/A
EXT OUT 69 N/A 9 58 9 6 9 9 5 N/A N/A
EXT OUT 70 N/A 9 57 9 7 0 9 6 N/A N/A
EXT OUT 71 N/A 9 56 9 7 1 9 7 N/A N/A
EXT OUT 72 N/A 9 55 9 7 2 9 8 N/A N/A
EXT OUT 73 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
10 54 10 7 3 10 1 N/A N/A
EXT OUT 74 N/A 10 53 10 7 4 10 2 N/A N/A
EXT OUT 75 N/A 10 52 10 7 5 10 3 N/A N/A
EXT OUT 76 N/A 10 51 10 7 6 10 4 N/A N/A
EXT OUT 77 N/A 10 50 10 7 7 10 5 N/A N/A
EXT OUT 78 N/A 10 49 10 7 8 10 6 N/A N/A
EXT OUT 79 N/A 10 48 10 7 9 10 7 N/A N/A
EXT OUT 80 N/A 10 47 10 8 0 10 8 N/A N/A
EXT OUT 81 N/A
Circle one:
None
Burg Output on 4-wire Burg Bus (BURG
GEMC-RM3008 or BURG GEMC-OUT8)
Fire Output on 4-wire Fire Bus (FIRE GEMC-
RM3008 or FIRE GEMC-OUT8)
Burg Output on Burg SLC 1 (GEMC-BSLC #1)
Burg Output on Burg SLC 2 (GEMC-BSLC #2)
11 46 11 8 1 11 1 N/A N/A
EXT OUT 82 N/A 11 45 11 8 2 11 2 N/A N/A
EXT OUT 83 N/A 11 44 11 8 3 11 3 N/A N/A
EXT OUT 84 N/A 11 43 11 8 4 11 4 N/A N/A
EXT OUT 85 N/A 11 42 11 8 5 11 5 N/A N/A
EXT OUT 86 N/A 11 41 11 8 6 11 6 N/A N/A
EXT OUT 87 N/A 11 40 11 8 7 11 7 N/A N/A
EXT OUT 88 N/A 11 39 11 8 8 11 8 N/A N/A
GEMC-NACXX
FIRE / BURG OUTPUT DEVICES (CONT'D)
Indicates not applicable for all options except GEMC-NACXX or FWC-FSLC-SOM1 placed on a Fire Output on Fire SLC 1 or Fire SLC 2.

Other manuals for NAPCO GEMINI GEMC-128

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO GEMINI GEMC-128 and is the answer not in the manual?

NAPCO GEMINI GEMC-128 Specifications

General IconGeneral
BrandNAPCO
ModelGEMINI GEMC-128
CategoryControl Panel
LanguageEnglish

Related product manuals