W415-0326 / 01.06.02
1
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
VENTED GAS FIREPLACE HEATER
NATURAL GAS MODEL
BGD48N
PROPANE GAS MODEL
BGD48P
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your build
ing.
• Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com • ask@napoleon.on.ca
R-2000

Questions and Answers

  • J
    Jose HallSep 9, 2025
    How to troubleshoot an over-fired or underfired Napoleon Indoor Fireplace?
    • J
      Julie HowardSep 9, 2025
      If your Napoleon Indoor Fireplace is over-fired or underfired, check the pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Check that the main burner is operating on "HI". After taking pressure readings, be sure to turn screws clockwise firmly to reseal. Do not overtorque.
  • J
    John DavisSep 8, 2025
    What to do if my Napoleon BGD48N is out of propane gas?
    • O
      osbornecraigSep 8, 2025
      If your Napoleon Indoor Fireplace is out of propane gas, fill the tank.
  • T
    Tricia DavisAug 25, 2025
    What to do if pilot light is burning but no gas to main burner in my Napoleon BGD48N?
    • R
      Ryan SmithAug 25, 2025
      If the pilot light is burning, but there's no gas going to the main burner on your Napoleon Indoor Fireplace, and the gas knob and wall switch/thermostat are on, here's what you can check: First, the thermopile connection to the valve may have shorted; clean the thermopile connection to the valve and reconnect it. The remote wall switch wire might be too long, causing too much resistance; shorten the wire to the correct length or wire gauge. As a last resort, replace the thermopile/valve.
  • J
    Jeffrey HowardSep 5, 2025
    How do I troubleshoot defective wall switch wiring in my Napoleon BGD48N?
    • J
      Jamie EvansSep 6, 2025
      To determine if the wall switch wiring is defective in your Napoleon Indoor Fireplace, disconnect the switch wires and connect a jumper wire across terminals 1 & 3; if the main burner lights, check the wires for defects and / or replace wires.
  • J
    Jesse MartinSep 4, 2025
    What to do if both the main burner and pilot light go out on my Napoleon Indoor Fireplace?
    • J
      Joseph AlvaradoSep 4, 2025
      If both the main burner and pilot light go out on your Napoleon Indoor Fireplace, allow approximately 60 seconds for the thermocouple to cool.
  • U
    usanchezSep 3, 2025
    How to adjust the pilot flame to engulf the thermocouple on my Napoleon Indoor Fireplace?
    • C
      Corey AguilarSep 3, 2025
      If the pilot flame is not engulfing the thermocouple on your Napoleon Indoor Fireplace, gently twist the pilot head to improve the flame pattern around the thermocouple.
  • F
    Francisco BenitezSep 1, 2025
    Why is the main burner flame blue and lazy on my Napoleon Indoor Fireplace?
    • K
      Kimberly RichSep 2, 2025
      If the main burner flame on your Napoleon Indoor Fireplace is a blue, lazy, and transparent flame, it could be due to a blockage in the vent; remove the blockage. Also, the air shutter may be blocked; ensure the air shutter opening is free of lint or other obstructions.
  • A
    Aaron SantiagoAug 31, 2025
    How do I check if the thermostat or switch is defective in my Napoleon BGD48N Indoor Fireplace?
    • C
      Courtney WhiteAug 31, 2025
      To check if the thermostat or switch is defective in your Napoleon Indoor Fireplace, disconnect a jumper wire across the wall switch terminals; if the main burner lights, replace the switch / thermostat.
  • R
    Ryan RomanAug 30, 2025
    How to troubleshoot a shorting or faulty thermocouple in my Napoleon BGD48N Indoor Fireplace?
    • F
      frenchleslieAug 30, 2025
      If the thermocouple is shorting or faulty on your Napoleon Indoor Fireplace, try the following: Loosen and then tighten the thermocouple. Clean the thermocouple and valve connection. If problems persist, replace the thermocouple or replace the valve.
  • M
    Michelle HillAug 29, 2025
    What to do if there's no gas at the pilot burner of my Napoleon BGD48N?
    • G
      George AdamsAug 29, 2025
      If there is no gas at the pilot burner of your Napoleon Indoor Fireplace, first check that the manual valve is turned on. Then, inspect the pilot orifice for any blockage. If neither of these resolves the issue, consider replacing the valve.

Napoleon BGD48N Specifications

General IconGeneral
TypeGas Fireplace
Fuel TypeNatural Gas or Propane
Ignition TypeElectronic Ignition
Vent TypeDirect Vent
Log MaterialCeramic Fiber
WarrantyLimited Lifetime Warranty