M
Michael RoachSep 5, 2025
How to adjust pilot flame to engulf thermocouple on Napoleon Furnace?
- SsmithzacharySep 5, 2025
To improve the flame pattern around the thermocouple, gently twist the pilot head.
How to adjust pilot flame to engulf thermocouple on Napoleon Furnace?
To improve the flame pattern around the thermocouple, gently twist the pilot head.
What to do if my Napoleon GD27 - N Furnace runs out of propane gas?
To resolve the issue of running out of propane gas, fill the tank.
How to check for defective wall switch wiring in my Napoleon GD27 - N?
To check for defective wall switch wiring, disconnect the switch wires from the valve and connect a jumper wire across terminals 1 & 3. If the main burner lights, check the wires for defects and replace them if necessary.
How do I test my Napoleon GD27 - N Furnace thermostat or switch?
To test if your thermostat or switch is defective, connect a jumper wire across the wall switch terminals; if the main burner lights, replace the switch/thermostat.
How to fix a grounding remote wall switch wire on my Napoleon GD27 - N Furnace?
To fix a grounding remote wall switch wire, check for a ground (short), repair the ground, or replace the wire.
What to do if the remote wall switch is grounding in my Napoleon GD27 - N?
If the remote wall switch is grounding, replace it.