EasyManua.ls Logo

National Instruments NI 6259 - Page 267

National Instruments NI 6259
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B-42 | ni.com
Appendix B Timing Diagrams
Table B-37 shows delays for generating different clocks using an External Reference Clock and
the PLL.
Figure B-53. Generating Different Clocks Using an External Reference Clock and the PLL
Table B-37. Generating Different Clocks Using an External Reference Clock and the PLL
Time From To Min (ns) Max (ns)
t
4
80 MHz Timebase 20 MHz Timebase 1.5 5.0
t
5
The source of the external
reference clock
(RTSI <0..7>, STAR_TRIG, PX
I_CLK10)
80 MHz Timebase
(through PLL_OUT)
1.0 5.5
RTSI <0..7>
STAR_TRIG
PXI_CLK10
(Reference Clock)
80 MHz Timebase (PLL)
20 MHz Timebase (PLL)
t
4
t
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com