Chapter 5 Counters
other applications, such as single pulse-width measurement, the counter begins waiting for the
Gate signal when it is armed. Counter output operations can use the arm signal in addition to a
start trigger.
Software can arm a counter or configure counters to be armed on a hardware signal. Software
calls this hardware signal the Arm Start Trigger. Internally, software routes the Arm Start Trigger
to the Counter n HW Arm input of the counter.
Routing Signals to Counter n HW Arm Input
Any of the following signals can be routed to the Counter n HW Arm input:
Any PFI terminal
AI Reference Trigger
AI Start Trigger
Analog Comparison Event
Change Detection Event
A counter’s Internal Output can be routed to a different counter’s HW Arm.
Some of these options may not be available in some driver software. Refer to the Device Routing
in MAX topic in the NI-DAQmx Help or the LabVIEW Help for more information about available
routing options.
Counter n Sample Clock Signal
Use the Counter n Sample Clock (CtrnSampleClock) signal to perform sample clocked
acquisitions and generations.
You can specify an internal or external source for Counter n Sample Clock. You also can specify
whether the measurement sample begins on the rising edge or falling edge of Counter n Sample
Clock.
If the cDAQ chassis receives a Counter n Sample Clock when the FIFO is full, it reports an
overflow error to the host software.
Using an Internal Source
To use Counter n Sample Clock with an internal source, specify the signal source and the
polarity of the signal. The source can be any of the following signals:
DI Sample Clock
DO Sample Clock
AI Sample Clock (ai/SampleClock, te0/SampleClock, te1/SampleClock)
AI Convert Clock
AO Sample Clock
DI Change Detection output

Table of Contents

Other manuals for National Instruments NI CompactDAQ 9184

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments NI CompactDAQ 9184 and is the answer not in the manual?

National Instruments NI CompactDAQ 9184 Specifications

General IconGeneral
BrandNational Instruments
ModelNI CompactDAQ 9184
CategoryChassis
LanguageEnglish

Related product manuals