EasyManuals Logo
Home>National Instruments>PCI Card>PCI-8361

National Instruments PCI-8361 User Manual

National Instruments PCI-8361
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
© National Instruments Corporation | B-17
MXI-Express x1 Series User Manual
Weight 0.15 kg (0.34 lb) typical
Power Requirements
Environment
Maximum altitude 2,000 m
Pollution Degree 2
Indoor use only.
Operating Environment
Ambient temperature range 0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity 10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage Environment
Ambient temperature range -40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Relative humidity range 5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Shock and Vibration
Operational shock 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Power Rail Typical Current Maximum Current
+3.3 V 555 mA 850 mA
+5 V 8 mA 10 mA
+12 V 10 mA 12 mA
-12 V 0 A 0 A
VIO 0 A 1 mA

Questions and Answers: