© National Instruments Corporation | A-39
MXI-Express x1 Series User Manual
Environment
Maximum altitude 2,000 m
Pollution Degree 2
Indoor use only.
Operating Environment
Ambient temperature range 0 to 65 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity 5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage Environment
Ambient temperature range -20 to 65 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Nonoperating thermal shock -20 to 65 °C, 5 shocks
Shock and Vibration
Nonoperating shock 50 g, 11 ms
(Tested in accordance with IEC 60068-2-27.)
Test profile developed in accordance with
MIL-PRF-28800F.
Nonoperating vibration sinusoidal 15 g 100 to 2000 Hz
(Tested in accordance with IEC 60068-2-6.)
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
Nonoperating drop test 2 drops in 3 mutually exclusive axes from 75 cm
onto no-cushioning vinyl tile surface