© National Instruments 51 NI sbRIO-960x/962x/963x OEM Instructions & Specifications
CMRR, DC to 60 Hz.............................. –80 dB
Input bandwidth (–3 dB) ........................ 600 kHz, typical
Settling error (multichannel scanning)... ±60 ppm step size, typical
Crosstalk (10 kHz) ................................. –70 dB
Typical performance graphs
CMRR (dB)
Frequency (Hz)
10 100
1000
10000
110
100
105
90
95
85
80
70
75
1 V Range
2 V Range
5 V Range
10 V Range
Normalized Signal Amplitude (dB)
Frequency (Hz)
1000 10000
100000
1000000
1
–2
–4
–7
8
–6
–5
3
–1
0