Table of Contents

Questions and Answers

  • M
    Michelle AndersonAug 19, 2025
    What to do if Natus Measuring Instruments has a missing or bad signal?
    • S
      Sandra ParkAug 20, 2025
      If you're experiencing a missing or bad signal with your Natus Measuring Instruments, try swapping cables to the Breakout Box. You can also run a channel test to diagnose the issue.
  • D
    Dakota MercerAug 29, 2025
    How to run a channel test on Natus Measuring Instruments?
    • S
      Samantha OlsenAug 29, 2025
      To run a channel test on Natus Measuring Instruments: 1. Set the LFF to 0.1 Hz on the montage settings toolbar. 2. Go to Controls->Channel Test. 3. Click Sine or Square in the first menu on the Channel Test control bar. 4. Adjust the waveform frequency and amplitude on the Channel Test control bar as needed.
  • A
    Austin HendricksNov 8, 2025
    What to do if acquired waveforms are flat on Natus Measuring Instruments?
    • J
      Jeffrey RiosNov 8, 2025
      If the acquired waveforms appear flat or are not displaying correctly on your Natus Measuring Instruments, try these steps: * Restart the computer for at least 10 seconds and restart the test. * Ensure the patient is relaxed. * Inspect all cables for damage. * Verify tight connections between the headbox, breakout box, and computer. * Confirm patient electrodes are correctly connected to the appropriate channel in the headbox. * Ensure patient electrodes fit securely into the headbox. * Check for breaks in the patient electrode cables. * Make sure that electrodes are not touching each other, as this can cause a short circuit. * Unplug other devices on the same circuit that may be causing interference. * Install a medical grade ground to ensure proper grounding of the e...

Summary

Introduction to Natus Amplifiers

Intended Use of the Amplifier

Specifies the medical applications and intended users of the amplifier system.

System Components and Operation

Essential Performance Standards

Defines the critical performance criteria for the amplifier.

Safety & Standards Conformity

Standards of Compliance and Normative References

Lists relevant international and national standards for safety and performance.

EMC Standard of Compliance and Normative References

Details compliance with electromagnetic compatibility standards.

Declaration of Compliance for IEC 60601-1-2

Electromagnetic Emissions Compliance

Outlines the electromagnetic emissions testing and compliance for the system.

Electromagnetic Immunity Declaration (Table 2)

Electromagnetic Immunity Declaration (Table 3)

Guidance and Declaration for Electromagnetic Immunity

Details immunity for equipment and systems that are not life-supporting.

RF Wireless Communications Equipment Immunity Test Specifications (Table 4)

Test Specifications for Enclosure Port Immunity

Lists test specifications for immunity to RF wireless communications equipment.

Declaration of Compliance for FCC

Contraindications, Warnings, & Cautions

Contraindications for System Use

Lists conditions under which the system must not be operated.

General Warnings and Cautions

Provides essential safety warnings and precautions for system operation.

Electrostatic Discharge (ESD) Precautions

Details necessary precautions to prevent damage from static electricity.

Electrical Warnings and Cautions

Highlights critical safety instructions related to electrical connections and servicing.

Patient Environment Warnings and Cautions

Specifies safety considerations for the patient's immediate surroundings.

Electrostatic Discharge (ESD) Handling Procedures

Provides detailed procedures for safely handling components susceptible to ESD.

System Specifications

System Setup Procedures

Connections and Cabling

Explains how to connect various system components and accessories.

Amplifier Usage and Features

Connecting System Components

System Maintenance

Electrical Input and Isolation Transformer Details

Pulse Oximeter Information

Pulse Oximeter Precautions and Warnings

Maintenance, Cleaning, & Disposal

Troubleshooting System Issues

Troubleshooting Checklist

A step-by-step guide to identify and resolve common system issues.

Problems with Signal Quality

Addresses specific issues related to poor or missing signal acquisition.

Getting Help and Technical Support

Appendix A: Digital Trigger Input Port Wiring

Appendix B: Headcap Connector Wiring

Appendix C: Frequency Response Curves

natus neuro Embla SDx Specifications

General IconGeneral
Sampling RateUp to 2048 Hz
Resolution24-bit
Impedance CheckYes
Noise Level< 1 μV RMS
Common Mode Rejection Ratio (CMRR)> 100 dB
Input Impedance> 100 MΩ
Operating System CompatibilityWindows
ConnectivityUSB
PowerBattery
High-pass Filter0.1 Hz
Notch Filter50 Hz or 60 Hz