Naucon-1000 test
Description of Naucon-1000
test menus
Revision: 1
17. august 2015
Page 3
Diagnostic troubleshooting guide.
This troubleshooting guide explains how the Diagnostic menu can be used.
Function
OK
Error
Fault
Relay 1
OK
Error
Cable or Horn connected to J7 faulty.
Relay 2
OK
Error
Cable or Horn connected to J8 faulty.
Relay 3
OK
Error
NG-Out or LED-Strip connected to J9 faulty.
12V In
OK
Error
No 12VAC supply.
12V Fuse
OK
Error
Fuse F1 blown.
24V In
OK
Error
No 24VAC supply.
24V Fuse
OK
Error
Fuse F2 blown.
Naunet 24V
OK
Error
Fuse F2 blown.
Naunet GND
OK
Error
Possible short circuit on equipment connected to
the NGMCB.
Extra 24V
OK
Error
*Fuse F12 blown.
Extra Relay
OK
Error
*N/A
DCF77
OK
Error
**NG-DCF has bad reception or is not installed
correct.
DIP1
Default is 0 00000000.
DIP2
Default is 0 00000000.
DIP3
Default is 11 00001011.
Diagnostic
Shows checksum.
Wireless Power
0-17. Can only be edited when test is started.
Press the Start test and thereafter the Reset test button at the bottom of the screen, for the Wireless-
test to begin.
Description.
OK.
Error.
Fault.
Total retry count
0
Counting.
Error in communication, see below.
Send packets
***Counting.
0
If 0, the radio in the Naucon-1000 could be
faulty.
Receive packets
***Counting
0
If 0, the radio on the NGMCB could be faulty.
Board receives
***Counting
0
If 0, the radio in the Naucon-1000 could beaulty.
Packet loss
0
Counting
Lost packets.
* Only displayed on Scoreboards with NGP’s mounted.
** Only displayed on Scoreboards with NG-DCF module mounted.
***Should approximately show the same value.
8