To determine the size of a common vent:
Venting Intake and Exhaust to Di
erent Locations
Venting Intake and Exhaust to the Same Location
12" (300mm) min.
12" (300mm) min.
36" (900mm) min.
Exhaust
Intake
Cap
Condensate
Drain
W
D
H
Exhaust
Intake
Condensate
Drain
Exhaust
Intake
Cap
Condensate
Drain
Model :
NPE-180(A,S)/ 210(A,S)/ 240(A,S)
Common Venting Guide
Condensing Water Heater
When cascading the water heaters with other Navien water
heaters, you can install a common venting system. Do not use
common venting if the water heater is used in a cascading system
with other manufacturer’s water heaters. Include a condensate
drain in the main trunk as illustrated in the following examples.
1. Add the BTU/H input ratings for each water heater in the
cascading system to determine the total BTU/H rating.
2. Determine the total length (L) of the common vent, which
consists of the horizontal width (W) and the vertical heigh
t
(H):
Total length (L) = W + H.
The following are examples of common venting options:
Venting the Exhaust Only (Non-Direct)
Intake
Exhaust
Cap
Condensate
Drain
W
D
H
DANGER
Improper DIP switch settings can cause severe personal
injury, death or substantial property damage.
Switch Function Setting
1 Cascade Vent
Common Vent
1-ONIndividual Vent
1-OFF
ONON
1 2 3 4 5 6 7 8 9 10 1 2
Downloaded from https://GadgetsGo.com

Other manuals for Navien NPE-240A

Questions and Answers:

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H