1.VerifyFRPsignalvaluereaches31,900psi(219,943kPa)atfullload.
2.VerifyFRPsignalvalueiswithina1000psi(6,895kPa)rangeofFRPDsignalvalueduring
acceleration.
NOTEAnalyzeLugDownTestsignalvaluesonlyduringengineacceleration,andnotdecelerationor
shifting.