1.VerifyIMPsignalvalueisbetween40psi(276kPa)to43psi(296kPa),withAcceleratorPedal
Position1(APP1)signalvalueat99.6%,andenginespeedbetween1300rpmto1700rpm.
NOTEAnalyzeLugDownTestsignalvaluesonlyduringengineacceleration,andnotdecelerationor
shifting.