Installation
Power Requirements/Connections
NCR 5635 Spray Currency Dispenser Service Manual 2-5
NCR - CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
Power Requirements/Connections
2
AC Power
2
The AC power for the dispenser must conform to the following
specification:
120VAC 5.5A RMS 20A surge
230VAC 3A RMS 10A surge
The required connector type is as follows:
Housing = Tyco Electronics 1-480 700-0
Crimp = Tyco Electronics 350218-0
DC Power
2
The DC power for the dispenser must conform to the following
specification:
+5V
±
5% 1.5A
+24V
±
5% 2A
The required connector type is as follows:
Housing = Molex 39-01-2165
Crimp = 39-00-0059
Live 1
Earth 2
Neutral 3
GND 1
+5V 2
GND 3
+5V 4
KEY 5
GND 6
+24V 7
master.bk Page 5 Wednesday, March 27, 2002 9:35 AM