Installation
Interface Connection
2-8 NCR 5635 Spray Currency Dispenser Service Manual
NCR - CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
The pin connections are as follows
Electrical
Connections
2
This interface is designed to the EIA RS 232 C standard. The
dispenser is configured as DTE (data terminal equipment) and uses
a subset of the handshake circuits.
RS 232 C is the default interface if no selection or enable links are
present. The connector configuration for this interface is as follows:
XRES 13 25 COMM_ID1
COMM_ID0 12 24 GND
E1 11 23 COMM_S1
GND1022COMM_S0
E0 9 21 DB
N/C 8 20 +5V
GRD 7 19 DA
N/C 6 18 OOO
CTS 5 17 LRTS
RTS 4 16 LCTS
RXD 3 15 LTXD
TXD 2 14 LRXD
SCRN 1
Pin 1 SCRN Cable screen
Pin 2 TXD Transmitted data, FROM the dispenser
Pin 3 RXD Received data, TO the dispenser
master.bk Page 8 Wednesday, March 27, 2002 9:35 AM