6.4 Key Operating Instruction
6.41 ”: ON /OFF button.
Short press ” to exit and return to the main interface.
In the main interface, long press and hold the “ ” key for 3 seconds to turn on / off.
6.42 Mode button.
In the power on state, long press for 3 seconds to switch the working mode: heating
mode and cooling mode.
6.43 ”: Add button.
When its turn on, in the main interface, press to adjust the setting temperature of
current mode;
6.44 ”: Reduce button.
When its turn on, in the main interface, press to adjust the setting temperature of
current mode
6.45 Parameters Query.
In the main interface, long press and hold the “ ” button for 3 seconds to enter the heat
pump status parameter query, Type “ , ” buttons for reading different parameters, and
press the “ button to exit the parameter query.
Heat pump status Parameter table
Inquiry Code
Description
Display Range
A01
Inlet water temp
-30~99
A02
Outlet water temp
-30~99
A03
Ambient temp
-30~99
A04
Discharge temp
0~125
A05
Suction temp
-30~99
A06
Outer coil temp
-30~99
A07
Inner coil temp
-30~99
A08
Main EV opening
0-480
A09
Assistant EV opening
0-480
A10
Compressor current
A11
Radiator temp
A12
DC bus voltage
A13
Compressor actual rotate speed
A14
DC fan motor actual rotate speed