20
MAIN SPECIFICATIONS
The following tables present the main technical specifications of the iPasolink 400 equipment. Some
performance data are given in Appendix A.
6, 7, 8, 10, 11, 13, 15, 18, 23, 26, 28, 32, 38, 42 GHz
Capacity per modem (*512QAM
Modem HW 2.00 and later)
1x155 Mbit/s tai
2x155 Mbit/s
External line signals and
interfaces
E1 (ITU-T G.703)
75/120 ohms
MDR-68 female (16xE1)
(See Appendix B and C).
S-1.1/L-1.1 (ITU-T
G.957): LC
ITU-T G.703: DIN
1.0/2.3
10/100/1000 Base-
T(X):RJ-45
1000 Base-SX/LX: LC
IDU-ODU connectors, cable
attenuation allowed
ODU: N-female 50 ohms
IDU: TNC-female 50 ohms
Maximum attenuation: 25 dB at 340 MHz
(E.g. Draka RFA ½” > 500m)
ODU RX level monitor connector
F-female (DC voltage proportional to the input level at antenna port)
Channel
spacing and
radio capacity
Environmental conditions
(ODU for outdoor use, IDU for
temperature-controlled indoor
use or outdoor cabinet with
similar conditions)
Full specifications: ODU: -33…+50 ˚C, IDU: -5…+50 ˚C
Operation guaranteed: ODU: -40…+55 ˚C, IDU: -10…+55 ˚C
Transportation: ODU, IDU: -40…+70 ˚C
Relative humidity: ODU: 100 %
IDU:
90 % (no condensing allowed)
-48 VDC (-40,5… -57 VDC),
Fuse/over current protection > 10A (6A for max 3 x ODU)
ODU: 30 W (6-11 GHz), 23 W (13-52 GHz)
IDU:
45 W + 10W/modem + 8W/GbE-card
Total < 210 W (fully equipped, feeding four 6 GHz ODUs)
ODU: 237(l)x237(w)x101(h); ~3-3,5 kg
IDU: 19” 1U (483x44x240mm); ~3-4 kg (including plug-in units)
LCT (local element
management)
LCT port: RJ45 10/100Base-T using a web browser
NMS/NE ports: RJ-45 10/100 Base-T
RS-232C 9600 bit/s 2 ch., V.11 64/192 kbit/s 2ch; D-44 female (See App. F)
External relay output/input
(AUX/ALM)
D-44 female (See Appendix F)
USB-port for a memory stick (USB v.2.0)
Table 4. NEC iPasolink 400 main technical data