ETHERNET SETTINGS
Provisioning -> ETH Function Setting
The Menu contains numerous L2 switch settings under Eth Function Setting. This chapter describes the
most common settings only.
Interface numbering
Ethernet ports are identified by the main card (MC-A4) or by the card type/slot number (GbE-A/Slot 1) as
well as the port number (Port01). Positions and ports are numbered from left to right. Port 1 and 2 are
electrical and port 3 and 4 are SFP slots.
Limitation: each card (MC-A4 or GbE-A) accepts only one type of SFP at a time. Port 3 and port 4 have to
have the same SFP inserted or port 4 has to be empty.
Bridge Setting
Figure 58 shows the recommended settings which should not be changed.
Note. The VLAN Mode (802.1Q tai 802.1ad) has to be identical in all IDUs in a cluster. Differing settings will
prevent remote management and connection to NMS.
Figure 58. L2 switch basic settings.
ETH Port Setting
Ethernet ports can be opened (Enable) and removed from use (Disable). The ports can be named.