15. Equipment Setup -> AMR / Radio Mapping Configuration -> Setup, New Setting
AMR Operation enabled = ”AMR Mode
Select modulation levels QSPK, 16QAM
Set the number of E1/STM-1 channels for each modulation level
16. Provisioning > Modem Function Setting
TX Power Setting: set the MTPC TX power (dBm) as given in the license
17. Provisioning -> E1/STM-1/Cross Connect Setting
enable the required E1-ports
cross-connect the E1 channels
18. Check the NMS connection
ping from the LCT port the NMS server IP address
request pinging test from the NMS server to the NMS port and Bridge1 addresses
request connection to be made to the NMS
19. Provisioning -> ETH Function Setting
enable Ethernet ports
make VLAN settings
make QoS setting
20. Reset PMON counters and the event logs.
Maintenance Control/PMON/RMON FDB Clear
Equipment Utility/Log Clear Function.